 1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
Features * Burst receive PON OLT transceiver * "Fast Signal Detect" feature reduces ranging overhead * Simplifed OLT "reset" timing * Small Form Factor, 2 x 10 pigtailed bi-directional * 1490 nm DFB Tx with isolator * 1310 nm APD Rx * 2488 Mbps downstream Tx/1244 Mbps upstream Rx * Single 3.3 V supply * ITU-T G.984.2 compliant * 20 km reach; 28 dB link budget * SC/UPC fiber connector; IEC 61754-4 compliant * RoHS-5/6 compliant (lead exemption)
Absolute Maximum Rating Parameter Supply Voltage Operation Relative Humidity Storage Temperature Maximum Receiver Input Power TX Disable Logic High State RX Reset Logic High State I2C Serial Data Logic High State I2C Serial Clock Logic High State Symbol Vcc_MAX RHs Tstg PIn_max TX_DIS_max Reset_max SDAmax SCLmax Min. 0 5 -40 +3 0 0 Typ. Max. 3.6 90 85 Vcc+0.5 Vcc+0.5 Vcc+0.5 Vcc+0.5 Unit V % C dBm V V V V
General Operating Parameter Operating Voltage Total Supply Current Case Operating Temerature (-CDE) Case Operating Temerature (-RDE) Case Operating Temerature (-TDE) Storage Temperature Symbol Vcc ICC Topr Topr Topr Tstg Min. 3.135 -5 -20 -40 -40 Typ. 3.3 Max. 3.465 450 70 85 85 85 Unit V mA C C C C
General Optical Parameters Parameter Back Reflection at 1490 nm Back Reflection at 1310 nm 1490 nm to 1310 nm crosstalk
Symbol
Min. -
Typ. -
Max. -20 -20 -45
Unit dB dB dB
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
1
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
Transmitter Specifications (Optical) Parameter Optical Power Average launch power of off Tx Wavelength Spectral Width (-20 dB) Side Mode Suppression Ratio Extinction Ratio Transmit eye mask Downstream Bit Rate +/- 100ppm Transmitter CID immunity Optical Rise timea Optical Fall timea Optical Path Penalty Tolerence to TX back reflectionb a) 20% to 80% values b) 1 dB degradation of receiver sensitivity 72 -15 2488 Symbol Pop Poff 20 SMSR ER Min 1.5 1480 30 10 Typical 1490 G.984.2 160 160 0.5 Mbps bits ps ps dB dB Max 5 -40 1500 1 Unit dBm dBm nm nm dB dB
Transmitter Specifications (Electrical) Parameter Input Differential Impedence Single Ended data input swing (ac coupled inside module) Tx Disable (LVTTL) Tx Enable (LVTTL) Tx_Fail_High (LVTTL) Tx_Fail_Normal (LVTTL) Symbol Rin Vin, p-p Vd Ven V_Fail V_Normal Min 80 300 2 0 2.4 0 Typical 100 Max 120 1200 Vcc 0.8 Vcc 0.4 Unit mV V V V V
Receiver Specifications (Optical) Parameter Wavelength Upstream Data Rate +/- 100ppm (burst-mode) Receiver Sensitivityc Receiver Overloadc Receiver Burst-mode Dynamic Ranged BRST_Det Assert (Signal Detected) Receiver CID Tolerance Maximum Reflectance of Receiver P_DET CID RX_r RENS ROL Symbol Min 1260 -8 15 72 Typical 1310 1244 -31 -5 20 Max 1360 -28 -28 -20 Unit nm Mbps dBm dBm dB dBm bits dB
c) At 10-10 BER with PRBS 223-1 Burst-Mode data at 1244 Mb/s d) The input power difference between two subsequent high and low burst data.
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
2
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
Receiver Specifications (Electrical) Parameter PECL Single ended data output swing(LVPECL) Data output rise timee Data output fall timee BRST_Det_High
f
Symbol Vout,p-p tr tf V_DETH V_DETL T_BRST_Det T_Reset_start T_Reset T_chatter
Min 250 2.4 0 -0.5 2 300
Typical 250 250 0 -
Max 800 Vcc 0.4 6.4 +1 -
Unit mV ps ps V V nS Byte Byte nS
BRST_Det_Lowf BRST_Det Response Time Reset Input Timingg Reset Input Duration RX output chatter time constanth
e) 20% to 80% values f) BRST_Det assert low when module receive "reset" signal, assert high when incoming burst is detected and latch to high state until next "Reset" signal. g) Timing for rising edge of "Reset" input singal is referenced to module pins with assumption of 4 bytes guard time after previous burst end h) RX output will start to chatter after T_chatter if there is no optical input or reset signal present.
I2C Serial Logic & Digital Diagnostic Monitor (DDM) Parameter I2C Serial Data High I2C Serial Data Low I2C Serial Clock High I2C Serial Clock Low TX Power DDM Error Case Temperature DDM Error TX Bias DDM Error Vcc DDM Error Symbol VSDA_H VSDA_L VSCL_H VSCL_L TXDDM TDDM TXBIASDDM VCCDDM Min 2.0 0 2.0 0 Typical Max Vcc 0.8 Vcc 0.8 +/- 3 +/- 5 +/- 10 +/- 0.3 Unit V V V V dBm C mA V
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
3
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
EEPROM Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Function Reset Pmon_analog RX_GND Reserved Reserved RX_GND RX_Vcc BRST_Det RXDRXD+ TX_Vcc TX_GND TX_DIS TXD+ TXDTX_GND SCL SDA TX_FAIL TX_GND Notes CMOS input. Assert "Reset" high at the end of previous burst, 2 bytes in duration Analog signal output for receiver optical input power monitoring Rx Ground No User Connection; Internal use No User Connection; Internal use Rx Ground Rx Vcc LVTTL output. BRST_Det assert low when module receives "reset" signal, assert high when incoming burst is present. Negative Data Output, LVPECL; DC coupled Positive Data Output, LVPECL; DC coupled Tx Vcc Tx Ground Tx Disable. LVTTL input. Laser output is disabled when this pin is asserted high or left unconnected. Laser output is enabled when this pin is asserted low. Positive Data Input, LVPECL or CML (AC coupled; internally 100 ohms differential termination) Negative Data Input, LVPECLor CML (AC coupled; internally 100 ohms differential termination) Tx Ground 2-Wire Serial Clock Input. Clocks data into and out of the device. 2-Wire Serial Data I/O Pin. Transfers serial data to and from the device. Tx Fail Alarm. LVTTL Output Active high. Tx Ground
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
4
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
Timing Diagram
Detailed burst-mode receiver timing diagram is available upon request.
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
5
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
EEPROM Content
DEC Addr.
HEX Addr.
Field Size (bytes)
Name
Default Value
Description
I2C A0h Address 0 00 1 1 01 1 2 02 1 3 03 8 11 0B 1 12 0C 1 13 0D 1 14 0E 1 15 0F 1 16 10 1 17 11 1 18 12 1 19 13 1 20 14 16 36 24 1 37 25 3 40 28 16 56 38 4 60 3C 2 62 3E 1 63 64 66 67 68 84 92 93 94 95 96 126 128 3F 40 42 43 44 54 5C 5D 5E 5F 60 7E 80 1 2 1 1 16 8 1 1 1 1 30 2 128
Identifier Extended Identifier Connector Transceiver Encoding Nominal Bit Rate in 100 MBps Reserved Length (9, km) in km Length (9, m) in 100 m Length (50) in 10 m Length (62.5) in 10 m Length (Copper) in m Reserved Vendor Name (ASCII) Reserved Vender IEEE Company ID Vendor Part Number (ASCII) Vendor Rev (ASCII) Laser Wavelength in nm Reserved Check Code for Base ID Fields Options Upper Bit Rate Margin in % Lower Bit Rate Margin in % Vendor Serial Number (ASCII) Date Code Diagnostic Monitoring Type Enhanced Options SFF-8472 Compliance Check Code for Extended ID Fields Vendor Specific Vendor Specific Reserved
02h 04h 0Bh (pigtail). 00 00 00 00 00 00 00 00h 03h 19h 00h 14h C8h 00h 00h 00h 00h "LUMINENTOIC " 00h 00 06 B5h "SFU4348HHPxDExxx" 31 20 20 20 05 D2h 00h xxh 00 1Ch 00h 00h "xxxxxxxxxxxxxxxx" xx xx xx xx xx xx 20 20h 58h E0h 02h xxh "SFU-43-48H-HP-xDE-xx " 0C 83h 00....00h
Module soldered to motherboard Function defined by serial ID Optical pigtail Transceiver Code Field, not applicable NRZ encoding 2488.32 Mbps Reserved 20km 20km Not Supported Not Supported Not Supported Reserved Vendor Name (ASCII) Reserved LuminentOIC IEEE ID Vendor Part Number (ASCII) Revision 1490nm Tx Wavelength Reserved Checksum from byte 0-62 TX_DIS, TX_Fault, SD BR, Max not specified BR, Min not specified 16 byte Serial number field (ASCII) Year(2 bytes) month(2 bytes) day(2 bytes) Ext Calibration, Average Power Measurement Optical Alarm/warning implemented Soft TX_DIS, TX_FAULT implemented Compliance to SFF-8472 Rev 9.4 Checksum from byte 64-69 LOIC part number (ASCII) Upstream Bit Rate (100 Mbps units) and Receive Wavelength (10 nm units) Reserved; return to 0
For detailed specifications of EEPROM contents and externally calibrated digital diagnostic monitor (DDM) functions, please refer to SFF-8472 standard Rev 9.5.
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
6
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
DEC Addr. HEX Addr. Field Size (bytes) Name Default Value Description
I2C A2h Address 0 00 2 2 02 2 4 04 2 6 06 2 8 08 2 10 0A 2 12 0C 2 14 0E 2 16 10 2 18 12 2 20 14 2 22 16 2 24 18 2 26 1A 2 28 1C 2 30 1E 2 32 20 2 34 22 2 36 24 2 38 26 2 40 28 16 56 38 4 60 3C 4 64 40 4 68 44 4 72 48 4 76 4C 2 78 4E 2 80 50 2 82 52 2 84 54 2 86 88 90 92 95 96 98 100 102 104 106 108 56 58 5A 5C 5F 60 62 64 66 68 6A 6C 6E.7 6E.6 6E.5 6E.4 6E.3 6E.2 6E.1 6E.0
LUMINENTOIC.COM
Temp High Alarm Temp Low Alarm Temp High Warning Temp Low Warning Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR(4) Calibration RX_PWR(3) Calibration RX_PWR(2) Calibration RX_PWR(1) Calibration RX_PWR(0) Calibration TX_I(Slope) Calibration TX_I(Offset) Calibration TX_PWR(Slope) Calibration TX_PWR(Offset) Calibration T(Slope) Calibration T(Offset) Calibration V(Slope) Calibration V(Offset) Calibration Reserved Checksum Transceiver Temperature Supply Voltage TX Bias Current TX Optical Output Power RX Optical Input Power Reserved Reserved TX_DIS State Soft TX Disable Reserved. Rate Select State Rate Select TX_FAULT LOS Data_ready_bar
xx xxh xx xxh xx xxh xx xxh 94 70h 6D 60h 8C A0h 75 30h 83 81h 02 64h 77 8Ch 03 96h xx xxh xx xxh xx xxh xx xxh FF FFh 00 00h FF FFh 00 00h 00....000h xx xx xx xxh xx xx xx xxh xx xx xx xxh xx xx xx xxh xx xx xx xxh 01 A3h 00 00h xx xxh xx xxh 01 00h xx xxh 01 00h 00 00h 00h xxh xx xxh xx xxh xx xxh xx xxh xx xxh 0000h 0000h x x 0 0 0 x 0 x
2 2 2 3 1 2 2 2 2 2 2 2 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit
80C (-CDE); 92C(-RDE); 92C(-TDE) -13C(-CDE);-28(-RDE);-48C(-TDE) 75C(-CDE); 87C(-RDE); 87C(-TDE) -8C(-CDE); -23C(-RDE); -43C(-TDE) 3.8V 2.8V 3.6V 3.0V 110mA 2mA 100mA 3mA +5.5 dBm +0.5dBm +5.0dBm +1.0dBm No alarm No alarm No alarm No alarm Reserved 4th order RSSI calibration coefficient 3rd order RSSI calibration coefficient 2nd order RSSI calibration coefficient 1st order RSSI calibration coefficient 0th order RSSI calibration coefficient Slope for Bias calibration Offset for Bias calibration Slope for TX Power calibration Offset for TX Power calibration Slope for Temperature calibration Offset for Temperature calibration, in units of 256ths C Slope for VCC calibration Offset for VCC calibration reserved Checksum Temperature in C/256 Vcc BIASMON Back facet monitor RSSI Reserved Reserved Digital state of the TX Disable Input Pin. Read/write bit that allows software disable of laser. Reserved. NOT SUPPORTED. NOT SUPPORTED. Digital state of the TX Fault Output Pin. Digital state of the LOS Output Pin. NOT SUPPORTED Indicates transceiver has achieved power up and data is ready.
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
110
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
7
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
DEC Addr.
HEX Addr.
Field Size (bytes)
Name
Default Value
Description
I2C A2h Address 6F.7 1bit 6F.6 1bit 6F.5 1bit 6F.4 1bit 111 6F.3 1bit 6F.2 1bit 6F.1 1bit 6F.0 70.7 70.6 70.5 70.4 70.3 70.2 70.1 70.0 71.7 71.6 71.5 71.4 71.3 71.2 71.1 71.0 72 73 74.7 74.6 74.5 74.4 74.3 74.2 74.1 74.0 75.7 75.6 75.5 75.4 75.3 75.2 75.1 75.0 76 77 78 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1 1 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1bit 1 1 8
Reserved Reserved Reserved Reserved Reserved INTERRUPT_NOT MODE_EN APD_SHUTDOWN Temperature too high alarm Temperature too low alarm VCC too high alarm VCC too low alarm BIASMON too high alarm BIASMON too low alarm BFMON too high alarm BFMON too low alarm RSSI too high alarm RSSI too low alarm Reserved interrupt status bit Reserved interrupt status bit Reserved interrupt status bit Reserved interrupt status bit Reserved interrupt status bit Reserved interrupt status bit Reserved Reserved Temperature too high warning Temperature too low warning VCC too high warning VCC too low warning BIASMON too high warning BIASMON too low warning BFMON too high warning BFMON too low warning RX Power High Warning RX Power Low Warning Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Vendor Specific
0 0 0 0 0 x 0 x x x x x x x x x x x x x x x x x 00h 00h x x x x x x x x x x 0 0 0 0 0 0 00h 00h 00 00 00 00 00 00 00 00h
112
113
114 115
Reserved Reserved Reserved Reserved Reserved Interrupt state (active low) TX FAULT pin enable APD shut-down latch. Write 0 to clear condition Temperature too high alarm Temperature too low alarm VCC too high alarm VCC too low alarm BIASMON too high alarm BIASMON too low alarm BFMON too high alarm BFMON too low alarm RSSI too high alarm RSSI too low alarm Reserved interrupt status bit Reserved interrupt status bit Reserved interrupt status bit Reserved interrupt status bit TX Fail went HIGH APD Shutdown event detected Interrupt Mask for ISRC0 Interrupt Mask for ISRC1 Temperature too high warning Temperature too low warning VCC too high warning VCC too low warning BIASMON too high warning BIASMON too low warning BFMON too high warning BFMON too low warning RSSI too high warning RSSI too low warning Reserved Reserved Reserved Reserved Reserved Reserved Interrupt Mask for ISRC2 Interrupt Mask for ISRC3 Vendor Specific
116
117
118 119 120
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
8
1490nm/1310nm Single Fiber OLT Transceiver
SFU-43-48H-HP-xDE
Outline Drawing
12.70 .500
13.97 .550
3.04 .120 TYP 1.02 2X .040 0.51 0.46 .020 .018
40.13 1.580 4.98 .196
12.45 .490 TABS
5.94 .234
PIN 1
PIN 10
1.27 .050 .010 .005
0.25 .010
10.16 .400 +0.25 12.70 0 +.010 .500 - .000
3.56 .140 D E TA I L A SCALE 8 : 1
PIN 20 8.89 .350 30.28 1.192
[1000 100] 39.370 3.937
1.78 .070 16 .630
PIN 11
4 PLACES
50.09 1.972
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
9
1490nm/1310nm Single Fiber SFFB Transceiver
SFU-43-48H-HP-xDE
Ordering information
Order Option: SFU-43-48H-HP-CDE n SFU-43-48H-HP-RDE SFU-43-48H-HP-TDE




Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC's sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company's standard one-year warranty; however, specifications designated as "preliminary" are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company's Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. (c) LuminentOIC, Inc. 2005 All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213
LUMNDS995-APR0207 Rev A.0 SHOR T FORM
10


▲Up To Search▲   

 
Price & Availability of SFU-43-48H-HP-RDE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X